Determine the location of the Collaboration Server on the rack:
Allow for a 1U gap above and below the system for ventilation.
Use the Rack Spacer (item no. 3) to predetermine its position on the rack
post, making sure that square studs of the spacer fit into the rack post's
square/rounded mounting holes. Mark the spacer's location on the rack
post. Repeat this process for the 3 remaining vertical posts ensuring that
the system can be horizontally seated.
Figure 1-1: Front view of RealPresence Collaboration Server (RMX) 2000/4000 rail