QB-V850MINIL, QB-V850MINI Emulator
Table 3-7. Mictor Connector Pin Functions (for V850E2, V850E1, or V850ES)
Pin No.
Signal Name
1 and 2
GND
3
DCK
4
V
DD
5
DMS
6
DRST#
7
DDI
8
RESET#
9
DDO
10
FLMD0
11
N.C
12
RESERVE
13
N.C
14
PORT0_IN
15
N.C
16
PORT1_IN
17
GND
18
PORT2_IN
19
GND
20
POWER
21 to 38
GND
Notes 1. As seen from the target device.
2. Refer to 3.5.4 Connecting the RESET# signal (for V850E2, V850E1, or V850ES).
3. Refer to 3.5.3 Connecting the FLMD0 signal (for V850E2, V850E1, or V850ES).
4. When the TRCCE signal (trace compression enable input) is connected as the trace interface for Renesas
Electronics partner company's emulator, the SW1 settings in QB-V850MINIL or QB-V850MINI must be
changed. Refer to 3.2.2 Switch settings for details.
R20UT0221EJ0400 Rev.4.00
2013.08.30
Note 1
I/O
−
Connect to GND
IN
Clock for DCU
−
Power supply (The power supply for buffers of a debugging interface, or
for power supply detection of a target system)
IN
DCU state transition control signal
IN
DCU reset signal
IN
Data signal transmitted to DCU
IN
System reset input signal (leave open when not used)
OUT
Data signal transmitted from DCU
IN
Flash programming mode setting signal (leave open when not used)
−
Open (not connected)
−
Open
−
Open (not connected)
−
Connect to GND
−
Open (not connected)
−
Connect to GND
−
Connect to GND
−
Connect to GND
−
Connect to GND
Note 4
−
Open
−
Connect to GND
3. On-Chip Debugging
Description
Note 2
Note 3
Page 49 of 86