Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 91

Table of Contents

Advertisement

NOTE
• The layout of excel files can be changed by editing the template file "Charts.xltx".
(An editable file can be found in C:\FREQROL\FRC2\dat\com\ChartTemplate.)
• Do not delete objects in the template file "Charts.xltx" or the file itself. Using a template file in which the original template has
been deleted will cause the error message "Export to Excel failed" to be displayed.
A template file used to export data to Excel when an error occurs can be found in the Configurator2 installation folder. (If the
location
C:\ProgramFiles\MELSOFT\FRC2\sys\Function\ChartTemplate.) Do not overwrite the template file. Instead, copy the
template file and use that file to make any changes.
 Communication manager
Online/offline can be switched for communication between FR Configurator2 and the inverter from the menu on the toolbar.
The online/offline condition of communication between FR Configurator2 and the inverter can be checked by the icon that is
displayed.
Display
NOTE
• When no communication is made for the period of the timeout time at online while "Ethernet" is selected for "PC-side port",
"TCP" for "Protocol", and "GOT" for "Through", a communication error occurs when communication is attempted next. After a
communication error occurs, the connection status is switched from online to offline. Switch the connection status to online
again to operate.
 Online/offline setting of the inverter and FR Configurator2 (Ethernet
connection)
• To connect the inverter and FR Configurator2 via Ethernet, refer to the following table to check the settings of the relay
device and parameters.
Model
Intermediate
Not connected
GOT
FR-A800-E
FR-F800-E
Programmable
controller
GOT to
programmable
controller
90
2. PROJECT CREATION
2.2 Explanation of the operating window of FR Configurator2
of
the
installation
Status
Offline
Online
Pr.
device
1427
1428
1429
1442 to 1448
1427
1428
1429
1427
1428
1429
1442 to 1448
1427
1428
1429
1442 to 1448
folder
has
not
been
Name
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
Ethernet function selection 1
Ethernet function selection 2
Ethernet function selection 3
IP filter address (Ethernet)
changed,
it
can
Setting
Set "5001" or "5002" in any of the parameters.
Set the IP address to within the IP address
range of the personal computer.
Set "5000", "5001", "5006", or "5008" in any of
the parameters.
Set "5001" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
Set "5001" in any of the parameters.
Set the IP address to within the IP address
range of the Ethernet module.
be
found
in