Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 64

Table of Contents

Advertisement

Pr.
Name
1330 to
User Defined Cyclic
1343
Communication Output 1 to 14
N850 to
Mapping
*1
N863
User Defined Cyclic
*1
Communication Input Sub 1
1389
and 2 Mapping
User Defined Cyclic
*1
Communication Input Sub 3
1390
and 4 Mapping
User Defined Cyclic
*1
Communication Input Sub 5
1391
and 6 Mapping
User Defined Cyclic
*1
Communication Input Sub 7
1392
and 8 Mapping
User Defined Cyclic
*1
Communication Input Sub 9
1393
and 10 Mapping
User Defined Cyclic
N830 to
Communication Input Sub 1 to
*1
N839
10 Mapping
User Defined Cyclic
*1
Communication Output Sub 1
1394
and 2 Mapping
User Defined Cyclic
*1
Communication Output Sub 3
1395
and 4 Mapping
User Defined Cyclic
*1
Communication Output Sub 5
1396
and 6 Mapping
User Defined Cyclic
*1
Communication Output Sub 7
1397
and 8 Mapping
User Defined Cyclic
*1
Communication Output Sub 9
1398
and 10 Mapping
User Defined Cyclic
N870 to
Communication Output Sub 1
*1
N879
to 10 Mapping
804
Torque command source
D400
selection
810
Torque limit input method
H700
selection
*1
The setting is applied after an inverter reset or next power-ON.
*2
The setting is available for the FR-E800-E only.
*3
The setting is available only for the FR-E800-EPB and the FR-E800-SCEPB.
Initial value
Setting range
*2
*2
6
, 101
, 12288 to
13787, 16384 to
16483, 20488,
20489, 20981 to
*3
20990, 20992
,
24639, 24643,
9999
24644, 24673 to
24676, 24692,
24695, 24820,
24826, 24828,
25858
9999
0 to 2, 256 to 258,
0
512 to 514
0 to 2, 256 to 258,
0
512 to 514
0 to 2, 256 to 258,
0
512 to 514
0 to 2, 256 to 258,
0
512 to 514
0 to 2, 256 to 258,
0
512 to 514
0
0 to 2
0 to 2, 256 to 258,
0
512 to 514
0 to 2, 256 to 258,
0
512 to 514
0 to 2, 256 to 258,
0
512 to 514
0 to 2, 256 to 258,
0
512 to 514
0 to 2, 256 to 258,
0
512 to 514
0
0 to 2
0
0, 1, 3 to 6
0
0 to 2
Description
Set the index number for inverter parameters, monitor
data, inverter control parameters, and CiA402 drive
profile. Functions can be assigned to remote registers
RWrn+4 to RWrn+1F when Pr.544 = "38".
Function disabled
Pr.1389 (lower 8 bits): Subindex to which the index
number is specified using Pr.1320Pr.1389 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1321
Pr.1390 (lower 8 bits): Subindex to which the index
number is specified using Pr.1322Pr.1390 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1323
Pr.1391 (lower 8 bits): Subindex to which the index
number is specified using Pr.1324Pr.1391 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1325
Pr.1392 (lower 8 bits): Subindex to which the index
number is specified using Pr.1326Pr.1392 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1327
Pr.1393 (lower 8 bits): Subindex to which the index
number is specified using Pr.1328Pr.1393 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1329
Subindices to which the index numbers are specified
using Pr.1320 to Pr.1329
Pr.1394 (lower 8 bits): Subindex to which the index
number is specified using Pr.1330Pr.1394 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1331
Pr.1395 (lower 8 bits): Subindex to which the index
number is specified using Pr.1332Pr.1395 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1333
Pr.1396 (lower 8 bits): Subindex to which the index
number is specified using Pr.1334Pr.1396 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1335
Pr.1397 (lower 8 bits): Subindex to which the index
number is specified using Pr.1336Pr.1397 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1337
Pr.1398 (lower 8 bits): Subindex to which the index
number is specified using Pr.1338Pr.1398 (upper 8 bits):
Subindex to which the index number is specified using
Pr.1339
Subindices to which the index numbers are specified
using Pr.1330 to Pr.1339
In the torque control mode, the torque command source
can be selected.
The torque limit input method can be selected.
1.4 Connection and parameter setting
1
2
3
4
5
6
7
8
9
10
63
1. OUTLINE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnd-frc2-e