 Detailed setting
Select [Detailed setting] in the "System setting" window, or select [Connection setting] in the "Source" window of the convert
function to open the "Detailed setting" window (the "Connection setting" window when the convert function is used). The items
for the detailed setting are determined according to the PC-side port and relay device settings specified in the system setting
window. Change the settings as required. The connection setting is in accordance with the initial value of the inverter.
A
C
E
F
G
H
Symbol
Name
A
PC-side port
B
COM Port No.
C
Through
D
Model
E
Timeout
Communication
F
speed
G
Data length
H
Stop bit
I
Parity
J
Delimiter
Restore initial
K
value
L
OK
M
Cancel
*1
Setting is available for connection setting using the convert function.
76
2. PROJECT CREATION
2.1 Project file operation
K
Initial
value
USB
Select a port for connection.
1
Specify the port number when "Specify the COM port number" is selected for the PC-side port.
Not used
Set a relay device.
Set a GOT model.
Set the time after transmitting data from the personal computer to the inverter until the personal
1000
computer receives a response from the inverter. When no response comes after the set time
elapsed, the error of "timeout occurs" is displayed.
19200
Set the communication speed. (Refer to Pr.118 and Pr.332.)
8
Set the data bit length. (Refer to Pr.119 and Pr.333.)
2
Set the stop bit length. (Refer to Pr.119 and Pr.333.)
Even
Specify the parity bit. (Refer to Pr.120 and Pr.334.)
CR
Specify the delimiter at the end of the data. (Refer to Pr.124 and Pr.341.)
A button to return the communication setting to the initial value of the inverter.
When the window is opened from the "System setting" window, click [OK] to close the window
and return to the "System setting" window. (Refer to
the "Source" window for the connection setting of the convert function, click [OK] to close the
window and return to the "Source" window. (Refer to
Clears the setting and closes the "Detailed setting" window.
Function/description
*1
*1
B
D
I
J
L
M
page
72.) When the window is opened from
page
122.)
*1