Parameter Clear / All Parameter Clear - Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual

Table of Contents

Advertisement

Symbol
Name
A
St. No. (Station number)
B
Operation mode button
C
Operation mode indication
D
Batch read
E
Read
F
Batch write
G
Write
H
All clear
I
Parameter clear
J
Verify
K
Undo
L
Redo
M
Open
N
Save as
O
Filter selection
P
Edit Individual list
Display of related
Q
parameters
R
Settings by function
S
Search
T
Back
U
Next
V
Target item
• Parameter list display item
Item
Number
Name
Setting range
Min. unit
Initial value
Setting value
NOTE
• To display the explanation about a parameter on the help window, double-click the parameter in the parameter list.
 To open the parameter file created on FR Configurator SW3 or SW1
• When the parameter file (*.pr3 or *.prm) created on FR Configurator SW3 or SW1 including both current values and setting
values is opened, "Choose parameter setting" window appears.
3.1.2

Parameter clear / all parameter clear

Performing parameter clear or all parameter clear will return the parameters to the initial values.
100
3. FUNCTION
3.1 Parameter list
Select a station registered in the project.
Switch between the operation modes of the inverter.
Displays the operation mode.
Reads all the parameter setting values of the selected inverter.
Reads the selected parameter setting values of the selected inverter.
Writes all the selected parameter setting values in the setting value column to the selected inverter.
Writes all selected parameter setting values to the selected inverter.
Returns all parameters which can be cleared including calibration parameters and terminal function
selection parameters to their initial values.
Returns parameters excluding calibration parameters and terminal function selection parameters to
their initial values.
Verifies the parameter settings set in FR Configurator2 against initial values, settings in parameter
files (*.pr4, *.pr3, *.prm), or settings in the inverter.
Returns the edited parameter setting value to the setting value before editing.
Redoes the setting value changed by "Undo" (up to 10 parameters).
Displays the "Open" dialog box for a parameter file (*.pr4, *.pr3, and *.prm) to be opened.
Shows the "Save as" dialog box. Verifies the save location, and saves with the specified [File Name].
The extension for savable parameter information files is *.pr4.
The parameter list data can also be saved in the Microsoft Excel file format (*.xls) by using "File
Type" in the "Save as" dialog box.
Used to select parameters shown in the parameter list.
Used to set the individual list for filtering items.
Used to display items related to the parameters selected in the parameter list.
Perform settings by function: motor, terminal, trace, and position control settings.
Searches for the input character string from within the parameter list.
Searches for the input character string in the downward direction.
Searches for the input character string in the upward direction.
Specifies the column to search.
Shows the parameter number.
Calibration parameters (Pr.902, 903, 904, 905, etc.) will be shown with ( ).
Shows the parameter name.
Shows the setting range of the parameter setting value.
Shows the minimum setting unit of the parameter setting value.
Shows the factory default parameter setting values of the inverter.
Inputs the value to be written to the inverter. The value different from the initial one is displayed in blue.
Selecting [Write] or [Batch write] will write the setting value field data to the inverter.
Function/description
Function/description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw1dnd-frc2-e

Table of Contents