Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 78

Table of Contents

Advertisement

 Network setting
When "Ethernet" is selected for the PC-side port, or "GOT", "Programmable controller", or "GOT to programmable controller"
is selected from the "Through" drop-down list, the "Network setting" window can be opened by clicking the [Network setting]
button in the "System setting" window.
Symbol
Name
A
St. No.
B
IP address
C
Port No.
D
Protocol
*1
Setting is available in the following conditions: "Not used" is selected from the "Through" drop-down list for the connection setting, or "GOT" is
selected from the "Through" drop-down list and "Ethernet" from "OUT port".
*2
When the station number switches are set to a value other than "0 (H00)" or "255 (HFF)", the switch setting is enabled. (For details on the station
number switches, refer to the CC-Link IE TSN Function Manual or FR-A8NCG Instruction Manual.)
*3
When the station number switches are set to "0 (H00)" or "255 (HFF)", the setting in the master station is enabled. (For details on the station
number switches, refer to the CC-Link IE TSN Function Manual or FR-A8NCG Instruction Manual.)
NOTE
• When "Ethernet" is set for the PC-side port and "TCP" is set for the protocol, a timeout may occur before the set timeout time
elapses. Since the TCP timeout on Windows is controlled by the operating system, a timeout occurs after the shorter timeout
time set in FR Configurator2 or the operating system elapses. The standard timeout time is about 20 seconds on Windows.
• When the "St. No." or "IP address" setting value is used by other model, the value is shown in red.
A
Set the station number. (For FR-A800-E, FR-F800-E, and FR-E800-(SC)E, refer to Pr.1425. For FR-
A800/FR-F800 inverter with FR-A8NCG in it, refer to Pr.437
For FR-E700-NE, refer to Pr.831.)
Enter the IP address. (For FR-A800-E, FR-F800-E, and FR-E800-(SC)E, refer to Pr.1434 to Pr.1437.
For FR-A800/FR-F800 inverter with FR-A8NCG in it, refer to Pr.434 to Pr.437
*1
refer to Pr.805 to Pr.808.)
Set the port number set in the inverter. (For FR-A800-E and FR-F800-E, refer to Pr.1427 to Pr.1429.
For FR-A800-E-R2R, refer to Pr.1076 to Pr.1078.) For FR-E800-(SC)E, refer to Pr.1427 to Pr.1430. For
FR-E700-NE, refer to Pr.833 to Pr.835.)
The "UDP" or "TCP" protocol is displayed.
D
B
C
Function/description
*2*3
. For FR-A800-E-R2R, refer to Pr.1074.
*2*3
. For FR-E700-NE,
10
77
2. PROJECT CREATION
2.1 Project file operation
1
2
3
4
5
6
7
8
9