Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 218

Table of Contents

Advertisement

Error code (HEX)
0x01808008
The communication line cannot
0x01808009
be opened.
0x0180800C
0x0180800D
0x01808501
USB communication was
0x01808502
interrupted.
0x01808506
The communication line cannot
0x80A00101
be opened.
0x80A00104
An unexpected error occurred in
0x80A00107
S/W.
0x80A0010A
The transmission data from the
computer was containing errors
0x80010000
for the permissible number of
retries or more.
The content does not match with
0x80010001
the specified parity.
The sum check code of the
computer is different from the
0x80010002
sum check code of the data
received by the inverter.
The data received by the inverter
contains a syntax error. Or the
0x80010003
inverter was not able to receive
the data within the specified
time.
The stop bit length is different
0x80010004
from the initial value.
Error message
Invalid Ethernet port number or IP
address.
Invalid communication port.
Invalid communication settings.
Invalid timeout value.
USB driver loading failed.
The USB driver failed to open.
USB driver initialization failed.
• Communication setting is not set
for the USB while connecting via
USB.
• No communication port exists on
the personal computer, or it is not
recognized.
Please contact your sales representative.
• The Pr.124 PU communication
CR/LF selection and Pr.341 RS-
485 communication CR/LF
selection settings are different
with the software settings.
• Electromagnetic interference.
• Cable breakage.
• The Pr.120 PU communication
parity check and Pr.334 RS-485
communication parity check
selection settings are different
with the software settings.
• Electromagnetic interference.
• Cable breakage.
• The communication setting is
different between the inverter and
the software.
• Data is corrupted due to
electromagnetic noise, etc.
• The Pr.124 PU communication
CR/LF selection and Pr.341 RS-
485 communication CR/LF
selection settings are different
with the software settings.
• Electromagnetic interference.
• Cable breakage.
• The Pr.119 PU communication
stop bit length / data length and
Pr.333 RS-485 communication
stop bit length / data length
settings are different with the
software settings.
• Electromagnetic interference.
• Cable breakage.
Possible cause
Check the communication settings.
Establish the online connection again.
• Check the connection type on the
[System setting] window. (Refer to
page
• Check that a communication ports
exists on the personal computer.
• Match the Pr.124 PU
communication CR/LF selection
and Pr.341 RS-485
communication CR/LF selection
settings with the software settings.
• Set a larger value in Pr.121 PU
communication retry count and
Pr.335 RS-485 communication
retry count.
• Replace the cable.
• Match the Pr.120 PU
communication parity check and
Pr.334 RS-485 communication
parity check selection settings with
the software settings.
• Set a larger value in Pr.121 PU
communication retry count and
Pr.335 RS-485 communication
retry count.
• Replace the cable.
• Make the same communication
setting.
• Check for electromagnetic noise and
wiring.
• Match the Pr.124 PU
communication CR/LF selection
and Pr.341 RS-485
communication CR/LF selection
settings with the software settings.
• Set a larger value in Pr.121 PU
communication retry count and
Pr.335 RS-485 communication
retry count.
• Replace the cable.
• Match the Pr.119 PU
communication stop bit length /
data length and Pr.333 RS-485
communication stop bit length /
data length settings with the
software settings.
• Set a larger value in Pr.121 PU
communication retry count and
Pr.335 RS-485 communication
retry count.
• Replace the cable.
Countermeasure
72.)