• The following functions are not converted, since they have been deleted from the FR-A800 series.
Pr.53 PU level display data selection
Pr.199 User initial value
Setting value 3 of Pr.200 to Pr.231 and Pr.76, setting value 5 of Pr.79, PRG signal (program operation)
Pr.371 Torque characteristic selection
Pr.390 to Pr.396 Trace function of the FR-A500L series
Pr.450 to Pr.453 Motor constant adjustment function for vector control of the FR-A500L series and FR-A5AP (encoder 50)
 To convert from FR-A500(L) inverters to FR-A802(-E) inverters
When the parameter settings are converted to the separated converter type, check the following items in addition to the items
mentioned in the previous page.
• After converting parameters, assign the X10 signal to an input terminal by setting of any of Pr.178 to Pr.189, and connect
the signal to the RDA signal of the FR-CC2.
• After converting parameters, assign the RES signal to an input terminal by setting of any of Pr.178 to Pr.189, and connect
the signal to the RSO signal of the FR-CC2.
• Set the following parameter as required in the "Parameter list" window because they are not converted depending on the
setting of the source inverter.
Pr.52 Operation panel main monitor selection
Pr.54 FM/CA terminal function selection
Pr.158 AM terminal function selection
Pr.190 to Pr.196 (I/O terminal function assignment)
Pr.306 Analog output signal selection
Pr.310 Analog meter voltage output selection
Pr.313 to Pr.322 (Output selection)
Pr.599 X10 terminal input selection
*1
Available when the plug-in option is connected.
• For the following parameters, set the FR-CC2 parameters as required.
Pr.57 Restart coasting time
Pr.65, Pr.67, and Pr.68 (Retry selection)
Pr.256 Inrush current limit circuit life display
Pr.258 and Pr.259 (Life of main circuit capacitor)
Pr.872 Input phase loss protection selection