Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 223

Table of Contents

Advertisement

Error code (HEX)
0x90010101
222
4. TROUBLE INDICATION
4.1 Error code
Error message
Communication was not
established with the inverter
within the timeout time.
Possible cause
• Electromagnetic interference.
• Cable is damaged or broken.
• The personal computer port is set
invalid or the port is broken.
• The value in the network part of
the IP address is not the same
between the inverter and the
personal computer. (Ethernet
parameter setting)
• The communication driver failed
to open.
• FR-A800-E/F800-E/E800-E
The value set in Pr.1432
Ethernet communication check
time interval is too small.
• FR-E700-NE
The value set in Pr.852 Ethernet
communication check time
interval is too small.
• FR-A800-E/F800-E
The function to communicate with
FR Configurator2 is not set in
Pr.1427 to Pr.1429 Ethernet
function selection.
• FR-A800-E-R2R
The function to communicate with
FR Configurator2 is not set in
Pr.1076 to Pr.1078 Ethernet
function selection.
• FR-E800-E
The function to communicate with
FR Configurator2 is not set in
Pr.1427 to Pr.1430 Ethernet
function selection.
• FR-E700-NE
The function to communicate with
FR Configurator2 is not set in
Pr.833 to Pr.835 Ethernet
function selection.
Countermeasure
• Reconnect or replace the cable.
• Activate the port using Device
Manager, or replace the port.
• Use the same value in the network
part of the IP address between the
inverter and the personal computer.
(Ethernet parameter setting)
• Establish the online connection.
• FR-A800-E/F800-E/E800-E
Set a larger value or "9999" in
Pr.1432 Ethernet communication
check time interval.
• FR-E700-NE
Set a larger value or "9999" in
Pr.852 Ethernet communication
check time interval.
"Ethernet" is selected from the "PC-side
port" drop-down list and "Not used" from the
"Through" drop-down list.
• FR-A800-E/F800-E
Set the combination of "5001" (or
"5002") and "45237" in any two of
Pr.1427 to Pr.1429.
• FR-A800-E-R2R
Set the combination of "5001" (or
"5002") and "45237" in any two of
Pr.1076 to Pr.1078.
• FR-E800-E
Set the combination of "5001" (or
"5002") and "45237" in any two of
Pr.1427 to Pr.1430.
• FR-E700-NE
Set the combination of "31" (or "32")
and "20" in any two of Pr.833 to
Pr.835.
"GOT" is selected from the "Through" drop-
down list and the GOT and the inverter are
connected via Ethernet.
• FR-A800-E/F800-E
Set "5001", "5000", "5006", or
"5008" in any parameter from
Pr.1427 to Pr.1429.
• FR-A800-E-R2R
Set "5001", "5000", "5006", or
"5008" in any parameter from
Pr.1076 to Pr.1078.
• FR-E800-E
Set "5001", "5000", "5006", or
"5008" in any parameter from
Pr.1427 to Pr.1430.
• FR-E700-NE
Set "31", "30", "36", or "38" in any
parameter from Pr.833 to Pr.835.
"Programmable controller" or "GOT to
programmable controller" is selected from
the "Through" drop-down list.
• FR-A800-E/F800-E
Set "5001" in any of Pr.1427 to
Pr.1429.
• FR-A800-E-R2R
Set "5001" in any of Pr.1076 to
Pr.1078.
• FR-E800-E
Set "5001" in any of Pr.1427 to
Pr.1430.
• FR-E700-NE
Set "31" in any of Pr.833 to Pr.835.