Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 88

Table of Contents

Advertisement

Menu
PU
EXT
NET
Batch read
Read
Batch write
Write
All clear
Parameter clear
Verify
Filter selection
Edit individual list
Display of related parameters
Parameter list
*1
(Z)
Motor
Settings
by
function
Terminal
Trace
Position
control
Batch read
Batch write
Safety parameter clear
Safety parameter
*1
setting (Z)
Verify
Password change
CIP Safety
Pull-down menu
Motor setting
Offline auto tuning
Acceleration/deceleration
pattern and time setting
Start command and
frequency setting method
Output terminal (FM/CA)
calibration
Output terminal (AM)
calibration
Input terminal assignment
Output terminal assignment —
Analog input terminal 2
calibration
Analog input terminal 4
calibration
Trace setting
Trace command
Point table
Read configuration
signature
Toolbar
Function/operation
icon
Activates the PU operation mode.
Activates the External operation mode.
Activates the NET operation mode.
Reads all the set values of the parameters of the
selected inverter.
Reads the set value of the selected parameter of the
selected inverter.
Writes all the parameter setting values entered in the
setting field to the selected inverter.
Writes the set value of the selected parameter to the
selected inverter.
Returns all parameters which can be cleared including
calibration parameters and terminal function selection
parameters to their initial values.
Returns parameters excluding calibration parameters
and terminal function selection parameters to their
initial values.
Verifies the parameter settings in FR Configurator2
against settings already written to the inverter.
Used to select parameters shown in the parameter list.
Displays the window for selecting items for the
individual list used as a parameter filter.
Displays items related to selected parameters.
Displays the window for the motor and the control
method setting.
Displays the window to perform offline auto tuning.
Displays the window for the acceleration/deceleration
and the time setting.
Displays the window for the start command and
frequency setting.
Displays the window to calibrate terminal FM/CA.
Displays the window to calibrate terminal AM.
Displays the window to assign functions to input
terminals.
Displays the window to assign functions to output
terminals.
Displays the window to calibrate terminal 2.
Displays the window to calibrate terminal 4.
Displays the window for the trace-related setting.
Displays the window to perform trace commands such
as sampling start/end.
Displays the window for the point table setting used for
position control.
Reads all the safety parameter setting values of the
selected inverter.
Writes all the safety parameter setting values in the
setting value column to the selected inverter.
All safety parameters and passwords return to initial
values.
Verifies the safety parameter settings in FR
Configurator2 against settings already written to the
inverter.
Changes the registered password.
Displays the window to check the details of the Safety
Configuration ID (SCID) and copy the ID.
2.2 Explanation of the operating window of FR Configurator2
10
87
2. PROJECT CREATION
1
2
3
4
5
6
7
8
9