Chapter 4 Trouble Indication; Error Code; Communication Error With The Inverter - Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual

Table of Contents

Advertisement

4
TROUBLE INDICATION
This chapter explains the trouble indications of this product.
Always read the instructions before using the equipment.
For the troubleshooting for firmware update, refer to
4.1

Error code

If an error occurs, the following error codes and error messages appear.
4.1.1

Communication error with the inverter

NOTE
• If a timeout error occurs, set the FR Configurator2 to the offline mode. Check the connection of the communication cable, etc.,
and remove any error causing condition, then set it to online.
• The parameter list of FR Configurator2 shows the parameters of the latest inverter at the time of the FR Configurator2 upgrade.
(For the upgrade timing of FR Configurator2, refer to
be different before and after a version upgrade (with functions added).
Error code (HEX)
0x010A4171
0x010AC201
0x01801006
0x01808201
214
4. TROUBLE INDICATION
4.1 Error code
page
Error message
A remote password is set.
The specified module does not
exist.
A data transmission error
occurred.
204.
page
227.) The parameters' setting range, initial value, and numbers may
Possible cause
A remote password is set for the
intermediate CPU or Ethernet
module.
An incorrect module is specified.
Transmission error.
Countermeasure
Delete the remote password set for
the CPU or Ethernet module.
Check the module type and model of
the programmable controller in the
system setting window.
Check the communication
environment.