Mitsubishi Electric MELSOFT FR Configurator2 Instruction Manual page 129

Table of Contents

Advertisement

*1
Available when the plug-in option is connected.
• If "63" is set in Pr.184 AU terminal function selection to enable the PTC thermal error detection (E.PTC) in the source
FR-F700 inverter, setting of Pr.561 and Pr.1016 and connecting the motor to the target FR-F800 inverter via terminals 2
and 10 are required. For the parameter details and terminal connection, refer to the Instruction Manual of the inverter.
 To convert from FR-F700(P) inverters to FR-F802(-E) inverters
When the parameter settings are converted to the separated converter type, check the following items in addition to the items
mentioned in the previous page.
• After converting parameters, assign the X10 signal to an input terminal by setting of any of Pr.178 to Pr.189, and connect
the signal to the RDA signal of the FR-CC2.
• After converting parameters, assign the RES signal to an input terminal by setting of any of Pr.178 to Pr.189, and connect
the signal to the RSO signal of the FR-CC2.
• Set the following parameter as required in the "Parameter list" window because they are not converted depending on the
setting of the source inverter.
Pr.30 Regenerative function selection
Pr.178 to Pr.189 (I/O terminal function assignment)
Pr.599 X10 terminal input selection
• For the following parameters, set the FR-CC2 parameters as required.
Pr.57 Restart coasting time
Pr.65, Pr.67, and Pr.68 (Retry selection)
Pr.256 Inrush current limit circuit life display
Pr.258 and Pr.259 (Life of main circuit capacitor)
Pr.872 Input phase loss protection selection
 To convert from FR-E700 inverters to FR-E800 inverters
• After conversion, set the following parameters as required in the "Parameter list" window as they are not converted.
Pr.69 Retry count display erase
Pr.170 Watt-hour meter clear
Pr.171 Operation hour meter clear
Pr.172 to Pr.174 (User group selection)
Pr.259 Main circuit capacitor life measuring
Pr.501 (Communication option parameter)
Pr.503 Maintenance timer 1
Pr.991 PU contrast adjustment
Pr.1006 to Pr.1008 (Clock function)
Pr.1200 AM output offset calibration
• The following parameters are used for adjustment. It is recommended to adjust the setting of the parameters again after
conversion according to the mechanical system.
Pr.0 Torque boost
Pr.12 DC injection brake operation voltage
Pr.323 AM0 0V adjustment
Pr.324 AM1 0mA adjustment
C2 (Pr.902) to C7 (Pr.905) (Frequency setting input calibration parameters)
128
3. FUNCTION
3.3 Convert