9.2.3 Swinging the air diverter open and closed

CAUTION
Prerequisite Unit switched off
Pinch hazard from rotating fan
• Before working on the unit, ensure that the unit has been disconnected from
the power supply.
• Do not operate the unit without the air diverter.
a
b
c
Image: Air diverter fastener
a Air diverter
b Upper fastener
c Lower fastener
Opening the air diverter
1. Remove the left support rack; present only in size 6 and size 10.
2. Loosen the upper fastener.
3. Loosen the lower fastener.
4. Loosen the center fastener; present only in size 20.
5. Swing the air diverter toward the back wall.
Swinging back the air diverter
1. Swing back the air diverter along the side wall.
2. Close the upper fastener.
3. Close the lower fastener.
4. Close the center fastener; present only in size 20.
5. Check the fasteners.
6. Insert the left support rack; present only in size 6 and size 10.
Maintenance instructions
Explanations regarding maintenance