Performing maintenance
8.12.2 Check and clean recirculation hood, replace filter
CAUTION
CAUTION
CAUTION
INFORMATION
28
Image: Cleaning the recirculation hood and filter
a Condensate baffle
b Filter drawer
c Air outlet
d Recirculation hood
Risk of injury from sharp edges
• Wear protective gloves.
Risk of burns from hot surfaces
• Allow surfaces to cool prior to cleaning.
Risk of falling from unstable climbing aids
• Use only approved ladders or step stools as climbing aids.
Do not operate the unit without air filter.
Maintenance instructions
d
c
b
a
h
g
e Vapor inlet
f Filter mat (yellow)
g Air filter
h Activated charcoal filter
f
e