Check Cooking Chamber Sensors Upper And Lower Cooking Chamber; Check Function Of Cooking Chamber Sensor; Result After Maintenance; Restoring The Unit To Operability - Henny Penny FlexFusion ELECTRIC SPACESAVER PLUS TEAM Maintenance Manual

Hide thumbs Also See for FlexFusion ELECTRIC SPACESAVER PLUS TEAM:
Table of Contents

Advertisement

Performing maintenance

8.15.3 Check cooking chamber sensors upper and lower cooking chamber

Check cooking chamber sensor
Test criteria
• Regulation works.
• Unit heats up and maintains set temperature.
If No
Change cooking chamber sensor.
Action

• Check function of cooking chamber sensor.

8.15.4 Check function of cooking chamber sensor
Prerequisite Unit switched on
Action
• Change the cooking chamber sensor.

8.16 Result after maintenance

Is the unit safe?
Test criteria
• The unit can be deemed as safe.
There are no reservations about unrestricted use.
If no
The unit is not safe. Disconnect the unit from power and inform the operator that customer service must repair the unit.

8.17 Restoring the unit to operability

Action
• Restore the unit to its operational state.
Handing over the unit
Test criteria
• Hand over the operational unit to the operator.
34
1. Start unit in cooking mode Convection with core temperature.
The unit heats up.
No error message appears in the display: Cooking chamber
sensor is working properly.
2. End cooking mode Convection with core temperature.
3. Switch off the unit.
The unit cools down.
Maintenance instructions
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsde 610

Table of Contents