7.13
Requirement

Swinging the air diverter open and closed

CAUTION
Pinch hazard from rotating fan
a) Prior to working on the unit, ensure that the unit has been disconnected
from the mains.
b) Do not operate the unit without the air diverter.
Air diverter fasteners on countertop and floor-standing units
a Air diverter
b Upper fastener
Swinging the air diverter open
➢ Unit switched off
a) Remove the left support rack; present only in size 6 and size 10.
b) Loosen the upper fastener.
c) Loosen the lower fastener.
d) Loosen the centre fastener; present only in size 20.
e) Swing the air diverter toward the back wall.
Swinging the air diverter closed
a) Swing back the air diverter along the side wall.
b) Close the upper fastener.
c) Close the lower fastener.
d) Close the centre fastener; present only in size 20.
e) Check the fasteners.
f) Insert the left support rack; present only in size 6 and size 10.
Cleaning and caring for the unit
Swinging the air diverter open and closed
c Lower fastener
d Centre fastener