Performing maintenance
Check siphon pump (service level / relay test)
Test criteria
If No
Troubleshooting according to service manual.
Inform operator.
Check pump circulation (service level / relay test)
Test criteria
• Pump circulation works properly.
If No
Troubleshooting according to service manual.
Inform operator.
Check motor cooking chamber for noise
Test criteria
• Motor cooking chamber runs virtually noiselessly.
If no
• Check fan wheel for imbalance.
• Recommendation of the manufacturer: Change motor and fan wheel.
Check electrical contacts - Carry out inspection of wiring harness (cable and contacts)
Test criteria
• Contacts are free of scorch marks.
If No
Change electronic components.

8.12 Check optional features

Inspecting the recirculation hood
Test criteria
• Recirculation hood works perfectly (hood runs).
If No
Do not continue to operate combisteamer until hood is repaired.

8.12.1 Check hand shower

Check hand shower
Test criteria
• Hand shower is tight.
• Hand shower works perfectly.
• undamaged.
If No
Check hose reel.
26
The following features may be available depending on the device.
Maintenance instructions
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Remarks / values
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsde 610

Table of Contents