3.3 Vacuum generator

The vacuum is generated by 7 battery-driven vacuum pumps (3). The vacuum generator is designed for smooth and air-
tight loads.
In order to save energy, the vacuum generator automatically switches off as soon as a vacuum of -0.7 bar is reached. The
vacuum generator automatically switches back on once the vacuum sinks below -0.63 bar.
DANGER
Danger of the load falling due to unauthorized adjustment of the automatic switch-off function
of the vacuum generator
Serious injury or death!
The vacuum generator's automatic switch-off has been optimally set at the factory and may not be
adjusted.

3.4 Suction plates

The suction plate is not included in the scope of delivery. It is used to pick up the load. The suction plate to be used de-
pends on the load (weight, geometry and surface properties).
Use only suction plates from the manufacturer Probst with carrying capacity labels that indicate without a doubt a maxi-
mum carrying capacity at a vacuum of -0,6 bar. If the situation is unclear, the lifting device and suction plate may not be
put into operation. Contact Probst GmbH.
Standard suction plates are not suitable for handling glass sheets.
52400046 / 52400048
Product description
17 / 58

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SH-2500-UNI-GL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Sh-2500-uni-gl-ffsSh-2500-greenline

Table of Contents