Integrating a device via HART protocol
50
• Expert ® Communication ® HART output ® Assign PV
• Expert ® Communication ® HART output ® Assign SV
• Expert ® Communication ® HART output ® Assign TV
• Expert ® Communication ® HART output ® Assign QV
The following measured values can be assigned to the device variables:
Measured values for PV (primary variable)
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
Measured values for SV, TV, QV (secondary, tertiary and quarternary variable)
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3
9.3

Other settings

In the HART configuration submenu, you can configure other settings for the HART protocol (e.g.
Burst mode).
Navigation path: Expert ® Communication ® HART config.
For an overview and description of the parameters of this menu, refer to the document
"Description of Device Parameters, Version for experts"
Proline Promass E TB2 HART