Endress+Hauser Proline Promass E TB2 HART Operating Instructions Manual page 54

Coriolis mass flow measuring system
Table of Contents

Advertisement

Commissioning
54
Parameters
Reference sound velocity
Enter the sound velocity of
the gas at 0°C (32°F).
Temperature coefficient
Enter the temperature
sound velocity
coefficient of the sound
velocity of the gas.
Pressure compensation
Enable the automatic
pressure correction.
Pressure value
Enter a value for the process
pressure to be used for
pressure correction.
Description
Selection/
User entry
0 to 99 999 m/s
Max. 15-digit, positive
floating-point number
• Off
• Fixed
0 to 99 999 [bar, psi]
Proline Promass E TB2 HART
Factory setting
0 m/s
0 (m/s)/K
Off
Country-dependent:
• 1.01325 bar
• 14.7 psi
Endress+Hauser