Commissioning
58
Parameters
Fixed reference density
Enter the fixed value for the
reference density.
Linear expansion coefficient
Enter the linear, fluid-
specific expansion coefficient
for calculating the reference
density.
Square expansion coefficient For media with a non-linear
expansion pattern, use this
function to enter a quadratic,
fluid-specific expansion
coefficient for calculating the
reference density.
Temperature unit
Select the unit for
temperature.
Result
The selected unit applies for:
– Current outputs
– Reference temperature
– Simulation process
variable
Reference temperature
Enter the reference
temperature for calculating
the reference density.
Current span
Select the current range for
the process value output and
for the upper and lower level
for signal on alarm.
4 mA value
Enter the value for the 4 mA
current.
20 mA value
Enter the value for the 20 mA
current.
Failure mode
Select the value the current
output adopts in an alarm
condition.
Failure current
Select the current value the
current output adopts in an
alarm condition.
Description
Selection/
User entry
Max. 15-digit, positive
floating-point number
0 to 1 [1/K]
0 to 1 [1/K
Unit picklist
Max. 15-digit floating-point
number with sign
• 4 to 20 mA NAMUR
• 4 to 20 mA US
• 4 to 20 mA
• Fixed current
Max. 15-digit floating-point
number with sign
Max. 15-digit floating-point
number with sign
• Min.
• Max.
• Last valid value
• Actual value
• Defined value
3.59 to 22.5 mA
Proline Promass E TB2 HART
Factory setting
Country-dependent:
• 1 kg/Nl
• 62.4 lb/Scf
0 [1/K]
2
2
]
0 [1/K
]
Country-dependent:
• °C (Celsius)
• °F (Fahrenheit)
Country-dependent:
• 20 °C
• 68 °F
Country-dependent:
• 4 to 20 mA NAMUR
• 4 to 20 mA US
Country-dependent:
• 0 kg/h
• 0 lb/min
Depends on country and
nominal diameter
Max.
22.5 mA