Diagnostics For The Configuration; Diagnostics For The Process - Endress+Hauser Proline Promass E TB2 HART Operating Instructions Manual

Coriolis mass flow measuring system
Table of Contents

Advertisement

Proline Promass E TB2 HART
Endress+Hauser
12.5.4

Diagnostics for the configuration

Diagnostics event
Event text
F410
Data transfer
F411
Up-/Download
C411
Up-/Download active Up-/Download active, please wait.
C431
Trim
F437
Configuration
incompatible
M438
Dataset
S441
Current output 1-2
C453
Flow override
C484
Simulation failsafe
mode
C485
Simulation process
variable
C491
Simulation current
output 1-2
12.5.5

Diagnostics for the process

Diagnostics event
Event text
S801
Supply voltage
M803
Current loop 1-2
S830
Ambient temperature
range
S831
Ambient temperature
range
S832
Ambient temperature
range
S833
Ambient temperature
range
S834
Process temperature
S835
Process temperature
S842
Process limit value
S862
Partly filled
F910
Measuring tube does
not vibrate
Diagnostics and troubleshooting
Remedial measures
1. Check connection.
2. Retry data transfer.
1. Check connection.
2. Retry data transfer.
Carry out trim.
1. Restart device.
2. Contact service.
1. Check data set file.
2. Check device configuration.
3. Up- and download new configuration.
1. Check process.
2. Check current output settings.
Deactivate flow override.
Deactivate simulation.
Deactivate simulation.
Deactivate simulation.
Remedial measures
Supply voltage too low!
Increase voltage.
1. Check wiring.
2. Change I/O module.
Reduce the ambient temperature around the
sensor housing.
Increase the ambient temperature around the
sensor housing.
Electronics temperature is too high!
Reduce ambient temperature
Electronics temperature is too low!
Increase ambient temperature.
Reduce process temperature.
Increase process temperature.
Low flow cut off active!
Check settings for low flow cut off.
1. Check for gas in process.
2. Adjust detection limits.
1. Check process conditions.
2. Increase supply.
3. Check main electronic or sensor.
Event level from the
factory
Alarm
Alarm
Warning
Warning
Alarm
Warning
Warning
Warning
Alarm
Warning
Warning
Event level from the
factory
1)
Warning
Warning
1)
Warning
1)
Warning
1)
Warning
1)
Warning
1)
Warning
1)
Warning
Logbook entry only
1)
Warning
Alarm