Accessories Compliant With Emc Standards; Electrosurgery Interference/Defibrillation - Philips IntelliVue CL SpO2 Instructions For Use Manual

Table of Contents

Advertisement

WARNING
For paced patients: The radiated SRR power of the IntelliVue SpO
Measurement Devices, the CL Transmitter, and other sources of radiofrequency energy, when used in
very close proximity of a pacemaker, might be sufficient to interfere with pacemaker performance.
Due to shielding effects of the body, internal pacemakers are somewhat less vulnerable than external
pacemakers. However, caution should be exercised when monitoring paced patients.
In order to minimize the possibility of interference, avoid positioning and wearing the Cableless
Measurement Devices in very close proximity to a pacemaker. Consult the pacemaker manufacturer
for information on the RF susceptibility of their products.
WARNING
For paced patients: The radiated WLAN power of the IntelliVue CL Transmitter, and other sources
of radiofrequency energy, when used in the proximity of a pacemaker, can be sufficient to interfere
with pacemaker performance. Due to shielding effects of the body, internal pacemakers are somewhat
less vulnerable than external pacemakers. However, caution should be exercised when monitoring any
paced patients.
In order to minimize the possibility of interference, position the IntelliVue CL Transmitter, when
body worn, as far away from the pacemaker as possible. Consult the pacemaker manufacturer for
information on the RF susceptibility of their products.

Accessories Compliant with EMC Standards

All IntelliVue CL SpO
Cableless Measurement Devices, with the requirements of IEC 60601-1-2:2001 + A1:2004.
WARNING
Using accessories other than those specified may result in increased electromagnetic emission or
decreased electromagnetic immunity of the IntelliVue Cableless Measurement Devices.

Electrosurgery Interference/Defibrillation

Measurement accuracy may be temporarily decreased while performing electrosurgery or defibrillation.
This does not affect patient or equipment safety. Do not expose the equipment to X-ray or strong
magnetic fields (MRI).
Pod and CL NBP Pod accessories comply, in combination with the IntelliVue
2
10 Specifications