• Port Error Recovery
•
Port Error Recovery
Timeout
The Industrial Managed PoE+ Switch implements the Rapid Spanning Protocol as the default
spanning tree protocol. When selecting "Compatibles" mode, the system uses the RSTP (802.1w)
to be compatible and to co-work with another STP (802.1D)'s BPDU control packet.
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
4.3.4.3 Bridge Status
This page provides a status overview for all STP bridge instances. The displayed table contains a row for each STP bridge
instance, where the column displays the following information: The Bridge Status screen in
The page includes the following fields:
Object
•
MSTI
•
Bridge ID
•
Root ID
•
Root Port
removed from the active topology.
Control whether a port in the error-disabled state automatically will be enabled
after a certain time. If recovery is not enabled, ports have to be disabled and
re-enabled for normal STP operation. The condition is also cleared by a system
reboot.
The time that has to pass before a port in the error-disabled state can be
enabled. Valid values are between 30 and 86400 seconds (24 hours).
Figure 4-3-4-5: STP Bridge Status Page Screenshot
Description
The Bridge Instance. This is also a link to the STP Detailed Bridge Status.
The Bridge ID of this Bridge instance.
The Bridge ID of the currently elected root bridge.
The switch port currently assigned the root port role.
174
User's Manual of IGS PoE series
Figure 4-3-4-5
appears.