That is, although the VLAN 2 members: Port-1 to Port-3 and VLAN 3 members: Port-4 to Port-6 also belongs to VLAN 1. But
with different PVID settings, packets form VLAN 2 or VLAN 3 is not able to access to the other VLAN.
6.
4.3.3.8.3 Port Isolate
The diagram shows how the Industrial Managed PoE+ Switch handles isolated and promiscuous ports, and the each PC is
not able to access the isolated port of each other's PCs. But they all need to access with the same server/AP/Printer. This
section will show you how to configure the port for the server – that could be accessed by each isolated port.
Setup steps
1.
Assign Port Mode
Set Port-1~Port-4 in Isolate port.
Set Port5 and Port-6 in Promiscuous port. The screen in
Repeat Steps 1 to 6, set up the VLAN Trunk port at the partner switch and add more VLANs to join
the VLAN trunk, repeat Steps 1 to 3 to assign the Trunk port to the VLANs.
Figure 4-3-3-15: The Configuration of Isolated and Promiscuous Port
Figure 4-3-3-15
appears.
159
User's Manual of IGS PoE series