• Power Supply Budget
[W]
• Temperature
Threshold
• PoE Usage Threshold
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
The wire gauge for the terminal block should be in the range of 12 ~ 22 AWG@25 degrees C.
PD Classifications
A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is
to provide information about the maximum power required by the PD during operation. However, to improve power management
at the PSE, the PD provides a signature about Class level.
The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input
voltages and operational modes.
A PD will return to Class 0 to 4 in accordance with the maximum power draw as specified by
Class
Usage
Default
0
Optional
1
Optional
2
Optional
3
Optional
4

4.6.1.4 Port Configuration

This section allows the user to inspect and configure the current PoE port settings as
Set limit value of the total PoE port providing power to the PDs.
Allows setting over temperature protection threshold value. If Its system
temperature is over the threshold then system will lower total PoE power
budget automatically.
Allows setting how much PoE power budget could be limited.
Range of maximum power used by the PD
0.44 to 12.95 watts
0.44 to 3.84 watts
3.84 to 6.49 watts
6.49 to 12.95 watts (or to 15.4 watts)
12.95 to 60 watts (or to 72 watts)
Table 4-6-1-1 Device Class.
347
User's Manual of IGS PoE series
Table 4-6-1-1.
Class Description
Classification unimplement
Very low power
Low power
Mid power
High power
Figure 4-6-1-3