Lat
ch/Reset
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 85
5
Latch/Reset is an application input. If the counter is reset via the application input, the
counter reading is held constant. The counter continues to remain fully functional and
operates in the background mode. During the next reset the current (updated) value will
be shown on the display.