description of the multifunction counter
Signals:
Signalzeiten:
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 78
4
General
P 1 and P 2 are available as relay changeover contacts and electronic output signals
(PNP). P 0 is available as an electronic output signal across the application output
(PNP).
If a signal is active, this will be shown on the LCD display.
Optionally, the multifunctional counter can be set to have the display flash if one or all
the preset values are acive.
This is also valid for Preset 0 (if no output has been assigned).
1.) bistable (latching): Cleared by electronic or manual reset.
P 0 + P 1= bistable – additionally cleared by signal 2
Attention: Signal 2 must not be bistable for automatic reset.
2.) monostable (timed): Up to 9 fixed signal times are available between 0,02s and 10s.
In addition, user times can be programmed between 0,01s to 599,99s.
3.) Range signals: active as long as the counter reading is within the adjusted range.