Current
mption
Power
mption
Duty cycle
Overload
tion
Overload protection
Relay output
Sensor supply
Storage of values
Electrical connections
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 249
10
Technical Data
12 ... 30 VDC < 200 mA,
consu
24 VAC < 250 mA; including sensor supply
115/230 VAC < 50 mA; incl. sensor supply
90 - 260 VAC < 400 mA; incl. sensor supply
< 5 W
consu
100%
external fuse DC: 0,16 AT (IEC 127); DC: 0,2 AT (UL 198)
protec
24 VAC: 315 mAT; 230 VAC: 32 mAT; 115 VAC: 63 mA T
external fuse 230 V, 2,5 mA T
Only for AC operation: 12-24 VDC load-dependent; max. 50 mA
NV-memory > 10 years
Plug-in screw-type connections / Terminals