Betriebsanweisungen_772_080909 engl_überarbeitet.indd 82
5
Pulse
1.) coincidence signal: The counter operates in the coincidence mode, i.e. output
signals are activated after reaching the Preset value for the programmed period
of time.
2.) Trail: P 2 and P 0 are under coincidence operation; they operate as described
in item A.
P 1 is the trail. P 1 is not absolute to 0, but relative to P 2.
If the setting is F8=1, the following will apply:
Signal 1 is returned at P 2 – P 1
Example: P 2=1000, P 1=200, Signal 1 at 800;
If P 1 is negative: P 2=1000, P 1=(-200), Signal 1 at 1200
If the setting is F8=2, the following will be applicable:
Signal 1 is returned at P 2 + and – P 1
(Example: P 2=1000, P 1=200, Signal 1 at 800 or/and 1200)
3.) range signal: P 1 and P 2 are range signals:
Signal 1 is active at a counter reading < P 1 and
Signal 2 is active at a counter reading > P 2
06.07.2010 10:31:51