description of the multifunction counter
Prescaler
(p
ulse
m
etering
fac
tor):
[PSC]
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 70
4
General
The "Prescaler" is a multiplier. Each input pulse is multiplied by the adjustment factor.
The display shows integers only. After a reset the counter is completely reset to 0; this
also includes the non-visible value of < 1.
At a prescaler of >1 not all the values are selectable. If invalid Preset values are
selected, the counter will round them up to the next possible value.
Example: PSC 5 cannot select (reach) Preset value 7. In this case, the counter
automatically changes the Preset value to 10.
If the Prescaler is changed, this may also affect the Preset values, which would have to
be changed accordingly.
Adjusting range 0,0001 to 99,9999
44
06.07.2010 10:31:51