operati
on:
Output
signals
-
mode
of
operati
on:
Reset
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 183
8
Shift
The counter operates in the "coincidence" mode, i.e. the output signals are
enabled for the programmed period of time after reaching the selected Preset
value.
The total sum acts on Preset 0
Partial sum 1 acts on Preset 1
Partial sum 2 acts on Preset 2
111
After a reset at input C, both partial sums and the total sum are reset.
When resetting via the application input it is possible to reset one or both of the
partial sums or the total sum, depending on the selected programming.
When resetting via the keyboard, only the value shown on the display is reset.
Counter