Hengstler Tico 772 Instruction Manual page 250

Hide thumbs Also See for Tico 772:
Table of Contents

Advertisement

Cable cross-section
Amplitude threshold
Active edge
Input resistance
Count frequency
Pulse form
Pulse duration min.
Prescaler
Reset
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 250
10
Technical Data
1...1.5 mm² with wire-end sleeves
< 2 V and > 8 V or < 1 V and > 4 V at TTL-level amplitude max. 40 VDC
programmable positive for PNP-input,
negativ for NPN-input
approx. 10 kOhm
max. 60 kHz (TTL 15 kHz): single-channel counting
max. 60 kHz (TTL 15 kHz): Different. counting and totalizing channel (A+B
together) max. 30 kHz (TTL 15 kHz): phase discriminator single or double
evaluation max. 15 kHz (TTL 15 kHz): phase discriminator, quadruple evaluation
damped (attenuated) 30 Hz
any desired form (at max. frequency square 1:1)
17 ms (30 Hz); 8 µs (60 kHz)
0,0001 - 99,9999
manual reset via keyboard,
external reset static or dynamic programmable; pulse length min. 5 ms,
06.07.2010 10:32:28