Current load of the outputs (Sensor 12-24 VDC, Out 1, Out 2, Application-Output) is
not allowed to exceed 65 mA in sum.
Counter
Counter mode of
operation Input A,B
add / add;
Control Input
Preselect Mode
Application Input/Output
Batch
Counter
Mode
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 253
10
Technical Data
152
Unidirectional; adding or subtracting; directional input;
Differential operation, add / sub; Summation (Totalizing)
Phase discriminator single, double or quadruple evaluation
Reset; Gate/Inhibit
Absolute or trail, Range signal /limit values (Signal 1 < P1, Signal 2 > P 2)
Output: Prescaler-out, Preset 0-out, Direction-out
Input: addtl. counter input add / sub, Reset, Set, Gate, Keylock, Hold, Teach in
Batch counter with Preset or 2nd totalizer with Preset