3.9
Prescaler
By pressing the Up + Shift keys simultaneously you can change to the Prescaler Programming Mode.
In the Programming mode, the position to be changed is selected by means of the shift key. The selected
position will start flashing. Use the shift key again to move by one position to the right. Then use the UP or
Down key to increment or decrement the position by 1. It is not possible to save a value of 00,0000. In this
case the system will save 01,0000.
Use the E key to leave the programming mode and return to the display mode. Your entries will be saved.
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 61
3
Setup and
38
programming
Operation
Set Preset
06.07.2010 10:31:48