Vibration resistance
Shock resistance
Resistence to chemicals
Approvals
RoHS
Mechanical
Data
Installation
Dimensions
Front-panel cutout
Weight
*
For cable length > 30 m, for connection to a DC-supply-network and input level TTL an additional
protection circuit is necessary.
Betriebsanweisungen_772_080909 engl_überarbeitet.indd 258
10
Technical Data
IP 20 terminals
10 m/s² (10 ... 150 Hz); IEC 60 068-2-6
100 m/s² (18 ms); IEC 60 068-2-27
Frontfoil acc. to DIN 42 115-2
UL, CSA (pending)
compliant
Front-panel installation with tenter (frame) Front panel thickness max. 11 mm
48 mm x 48 mm x 118 mm, installation depth 110 mm DIN 43700
45 mm x 45 mm + 0,3 mm
approx. 200 g