12.4
Length of cable
12.5
Table of weights
8024467/2019-06-18 | SICK
Subject to change without notice
Protective field height in mm
1500
1650
1800
1950
2100
1)
Power discharged again via the OSSDs depending on the connected OSSD load must be added to the
table values.
Table 14: Maximum lengths of cable for wire cross-section 0.34 mm
Separate connecting cables for
sender and receiver
Connection of sender and receiver
via T-connector on the sender
Connection of sender and receiver
via T-connector on the receiver
S
Control cabinet with safety relay or safety controller
T
T-connector
Table 15: Weight of sender and receiver
Protective field height in mm
300
450
600
750
900
1050
1200
1350
1500
Typical power consumption for
sender in W
Resolution 30 mm
1.20
1.25
1.30
1.34
1.39
Single system
s
s
r
r
b
c
S
b ≤ 85 m
s
s
r
r
T
c
a
S
a + c ≤ 15 m
s
s
r
r
T
b
a
S
a ≤ 15 m
Weight in g
1)
s Sender
290
430
570
700
840
970
1110
1240
1380
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes
12
TECHNICAL DATA
Typical power consumption for
receiver in W
1)
Resolution 30 mm
2.40
2.50
2.59
2.69
2.78
2
, copper wire
c ≤ 15 m
b ≤ 85 m
r Receiver
300
440
580
710
850
980
1120
1250
1390