FRU List (Continued)
TABLE 4-1
Part Number
FRU Name
6211630-01
0815033
6204202-01
6240320-01
Tape Drive Distribution PWA
6240330-01
Tape Drive MUX PWA
6210440-01
6210515-03
X-Axis Confirmation Sensor
6210470-01
6210450-01
0355038
Motor Power Supply Assembly
0355041
PC Logic Power Supply Assembly

X-Axis Interconnect PWA

Required Tools

Phillips screwdriver, flashlight

To Remove the X-Axis Interconnect PWA

1. Remove power from the library.
Caution - DO NOT disconnect the power cord from facility power or the library.
The power cord is the only means of grounding the chassis and helping to prevent
electrostatic discharge (ESD) damage.
2. Remove the top, left, and right side cosmetic panels as shown in "Top, Right, and
Left Panels" on page 92.
3. Connect your ESD wrist grounding strap to the closest grounding point on the
library frame.
4. Move the horizontal axis to the front of the library positioning the gripper
directly under the tape drives.