TABLE B-1
Sense
Key
4
4
4
4
B
4
4
198
Sun Enterprise Tape Library 7/3500 Field Service Manual • July 1997
Sense Data Values (Hexadecimal) (Continued)
ASC
ASCQ
Message Name/Description
8D
06
DLT DRIVE HANDLE MOTOR CURRENT
FEEDBACK TEST FAILURE
Unable to sense current feedback from
stepper motor controller during self-test.
Check motor cable connections.
8E
01
FLASH MEMORY UNABLE TO IDENTIFY
Flash is soldered onto the board. Replace the
robotic controller.
8E
02
FLASH MEMORY UNABLE TO ERASE
Flash is soldered onto the board. Replace the
robotic controller.
8E
03
FLASH MEMORY UNABLE TO PROGRAM
Flash is soldered onto the board. Replace the
robotic controller.
8F
00
LIBRARY UNIT COMMAND TIMED OUT
Verify that communications to library still
exists by issuing another command
F3
02
DLT DRIVE COMMUNICATION TIMEOUT
The library is unable to communicate with a
drive.
F3
11
DLT DRIVE HANDLE NOT OK
The tape drive is reporting that the handle
cannot open. (This may indicate that a DLT
cartridge is present that has not been
unloaded.)
Interface