Mec Speed Level 2684 RT Service And Parts Manual page 122

Sigma lifts
Table of Contents

Advertisement

Table 4a-3: EZ-Cal Diagnostics Menu
SELECTION
ID
2F
2F-1
OUTPUTS
2F-2
2F-3
2F-4
2F-5
2F-6
2F-7
2F-8
2F-9
2F-10
2F-11
2F-12
2F-13
2F-14
2F-15
2F-16
2F-17
2F-18
2F-19
2F-20
2F-21
2F-22
2F-23
2F-24
2F-25
2G
2G-1
LOG
2G-2
2G-3
November 2009
Page 4a-18
T
R O U B L E S H O O T I N G
EZ-cal
EXPLAINATION
READOUT
P4-1
Choke (gas engine) or pre-heat (diesel). ON= Choke or Pre-heat activated
P4-2
Engine Start. ON= Starter activated
P4-4
Throttle Solenoid. ON= Throttle solenoid pulled in
P4-5
Fuel to fuel select switch. ON= fuel system activated
P4-6
Fuel to fuel select switch. ON= fuel system activated
P4-7
Alternator Excite. ON= power to activate alternator charge
P4-8
Ignition. ON= power to ignition coil (gas) or fuel hold solenoid (diesel)
P4-10
Rear Wheel Bi-pass Valves. ON= Valves powered, rear wheels in bi-pass
P4-12
Proportional Valve. ON= Proportional valve activated for lift and drive operation
P4-14
Down Valves. ON= Down valves activated for platform lower operation
P5-1
Lift Valve. ON= Lift valve activated for platform Lift
P5-2
Steer Right. ON= steer right valve activated
P5-3
Steer Left. ON= steer left valve activated
P5-4
Drive Forward. ON= drive forward valve activated
P5-5
Drive Reversed. ON= drive reverse valve activated
Alarm. ON= alarm activated (default alarm in Down, may be selected for other
P5-6
modes)
High Torque. ON= high torque valve activated (drive range toggle in down
P5-7
position)
P5-8
High Speed. ON= high speed valve activated (drive range toggle in up position)
P5-9
Hour Meter. ON= Meter powered up
Power Supply to limit switch and TBM module - should be ON when system
P5-12
powered
P6-1
Rear Pitching Valve. ON= rear pitching valve activated for Platform Rear Leveling
Front Pitching Valve. ON= Front Pitching valve activated for Platform forward
P6-2
Level
P6-3
Outrigger – Not used
P6-4
Left Rolling Valve. ON= Left valve activated for platform Level Left
P6-11
Axle Lock Valves. ON= Axle valves powered, front axle will oscillate
Cal Date
Date of Load Sense calibration (CE option only)
Software
MEC specific software version
Powered
Accumulated time GP400 powered up (red LED on)
"3084 Speed Level™ Sigma Lift" Service and Parts Manual
- 3 0 8 4 R T
- - E Z - C
M O D E L S
A
A L
D J U S T M E N T

Advertisement

Table of Contents
loading

Table of Contents