Mec Speed Level 2684 RT Service And Parts Manual page 118

Sigma lifts
Table of Contents

Advertisement

Table 4a-1: EZ-Cal Adjustment Table
OPERATION
ID
5F
5F-1
OUTRIGGERS
5F-2
5F-3
Called
5F-4
"Outriggers" on
5F-5
the EZ-Cal,
5F-6
these
personalities
5F-7
effect
5F-8
Auto-level
5F-9
function
5F-10
5F-11
5G
5G-1
GROUND MODE
5G-2
Lower Control
5G-3
Operations
5G-4
5G-5
5G-6
5H
5H-1
TILT
5H-2
5H-3
5H-4
TILT 2
5H-4
Sub Menu
5H-5A
5H-5B
5H-5C
5I
5I-1
OVERLOAD
5I-2
5I-3
ANSI: values = 0
5I-4
5I-5
CE: values apply
5I-6
5I-7
OVERLOAD 2
5I-8
Sub Menu
5I-8a
5I-8b
5J
5J-1
ALARMS
5J-2
5J-3
5K
5K-1
HEIGHTS
5K-2
5K-3
5K-4
5K-5
5K-6
5K-7
5K-8
November 2009
Page 4a-14
T
R O U B L E S H O O T I N G
PERSONALITY
FACTORY SETTING EXPLAINATION
Outriggers
Extend
Level
Retract
Debounce
Initial
Tilt filter
X Tilt target
Y Tilt target
Tilt Slack
Outrigger Test
UP
DOWN
OUT
IN
ACCEL
DECEL
X Trip
Y Trip
Delay Trip
Delay Clear
Tilt 2
At Height
X Trip 2
Y Trip 2
Trip @
ANSI: 0% || CE: 110% % of weight over maximum to trigger overload
Lamp @
ANSI: 0% || CE: 0%
Alarm @
ANSI: 0% || CE: 0%
@ Height
ANSI: 0% || CE: 8%
Safe Down
ANSI: 0% || CE: 12%
Delay Trip
Delay Clear
Overload # 2
@ Height
Scale
Drive: Yes/No
Lift
Tilt
1 = When Elevated
Elevation
Maximum Drive
Maximum Lift
ANSI: 101% || CE: 98% Maximum elevated height potential
Armguard
Overload
ANSI: 0% || CE: 8%
Safe Down
ANSI: 0% || CE: 12%
Overload # 2
Tilt # 2
ANSI: 0% || CE: 0%
"3084 Speed Level™ Sigma Lift" Service and Parts Manual
- 3 0 8 4 R T
2
Not Used
50%
O/R speed before all legs down
35%
O/R speed after all legs touch down
55%
Maximum speed potential
0.35
Compensates for switch bounce
0.5
Not Used
6
Compensates for tilt sensor free movement
0.2 deg
Target level stops movement
0.2 deg
Target level stops movement
0.3 deg
Additional compensation
Yes/No
Not Used
53%
Maximum speed potential
0%
Gravity down
0%
Power deck operation (not used)
0%
Power deck operation (not used)
1.0 sec
Ramp-up time to maximum
1.0 sec
Ramp-down drive output
2.0 degrees
Angle tilt sensor signals Out Of Level
2.0 degrees
Angle tilt sensor signals Out Of Level
2.0 sec
Time delay between Tip and Signal
0.5 sec
Time delay between Tip and Signal OFF
Sub category, press ENTER to access
101%
Point where lesser tilt angle used
1.5 sec
Not Used
1.5 sec
Not Used
% of weight over maximum to trigger lamp
% of weight over maximum to trigger alarm
% of elevation load sense starts monitoring weight
% of elevation lift-down still operates in overload
1.5 sec
Delay before overload trip
1.5 sec
Delay before overload clear
Sub category, press ENTER to access
0%
% of height for secondary overload valve
100%
% of reduced overload valve
No
1 = FWD 2 = REV 3 = Both 4 = All Motion
2 = Down
1 = UP 2 = DOWN 3 = Both 4 = All Motion
1 = When Elevated 2 = Always
15%
Point at which machine enters elevated mode
101%
Maximum drivable height
101%
Stops descent for 5 sec
% of elevation load sense starts monitoring weight
% of elevation lift-down still operates in overload
0%
Not Used
Reduced degree of tilt at % elevation