Function description
4.9.1

Access to I/O data types

Data access is via pre-defined I/O data types:
Input data types
I-data
I-data type
name
I00 ... I03 FS_I_DI
FS_I_FAU_SIGNALS
FS_I_FAU_FAST_SHUT-
DOWN_TRIGGERED
Operating Manual PSSu K F FAU B, PSSu K F FAU P
1003434-EN-05
I-data element
Meaning
Data: SAFEBOOL
Input data I00 ... I03
OSSD: SAFEBOOL
TRUE: Protected field clear
FALSE: Protected field broken
Mute: SAFEBOOL
TRUE: PSENvip is not in dynamic muting
FALSE: PSENvip is in dynamic muting
OverrunMeasure-
TRUE: Overrun measurement active,
ment: SAFEBOOL
overrun measurement field not interrup-
ted, overrun not too long
FALSE: Overrun measurement inactive or
overrun measurement field interrupted
and overrun too long.
I0: SAFEBOOL
TRUE: Input has triggered the fast shut-
down
I1: SAFEBOOL
FALSE: Input has not triggered the fast
I2: SAFEBOOL
shutdown
I3: SAFEBOOL
OSSD: SAFEBOOL
TRUE: OSSD has triggered the fast shut-
down
FALSE OSSD has not triggered the fast
shutdown
MUTE: SAFEBOOL
TRUE: The MUTE signal of the advance
measuring field has triggered the fast
shutdown
FALSE: The MUTE signal of the advance
measuring field has not triggered the fast
shutdown
| 23