Safety Characteristic Data - Pilz PIT es Set10u-5ns (AIDA) basic Operating Manual

E-stop device
Hide thumbs Also See for PIT es Set10u-5ns (AIDA) basic:
Table of Contents

Advertisement

PIT es Set10u-5ns (AIDA) basic
Environmental data
Protection type
Housing
Front
Mechanical data
Mounting position
Connection type
Dimensions
Height
Width
Depth
Weight
Where standards are undated, the 2017-08 latest editions shall apply.

Safety characteristic data

Operating mode
Perceptibility of red illumina-
tion in defined ambient condi-
tions
Operating mode
N/C contacts
All the units used within a safety function must be considered when calculating the safety
characteristic data.
Please note that the Performance Level in accordance with EN 13849-1 can be reduced
because of reduced fault detection when several E-STOP devices are cascaded.
Operating Manual PIT es Set10u-5ns (AIDA) basic
1004863-EN-03
400463
IP65
IP65
400463
Any
M12
103,2 mm
72 mm
91,8 mm
207 g
NOTICE
You must comply with the safety characteristic data in order to achieve the
required safety level for your plant/machine.
EN ISO 13849-1:
EN ISO 13849-1:
2015
2015
PL d
Cat. 2
NOTICE
Only one PIT es Set10u may be used per circuit (no cascading).
400464
IP65
IP65
400464
Any
M12
103,2 mm
72 mm
91,8 mm
207 g
EN ISO 13849-1:
2015
PFH
[1/h]
D
3,00E-07
EN ISO 13849-1: 2015
B10d
100.000
EN ISO 13849-1:
2015
T
[year]
M
20
| 19