Technical details
Times
Max. reaction time of fast shutdown
when signal changes from "0" to
"1" (depending on the configured
input filter time)
Environmental data
Climatic suitability
Ambient temperature
In accordance with the standard EN 60068-2-14
Temperature range
Storage temperature
In accordance with the standard EN 60068-2-1/-2
Temperature range
Climatic suitability
In accordance with the standard EN 60068-2-78
Humidity
Condensation during operation
Max. operating height above sea
level
EMC
Vibration
In accordance with the standard EN 60068-2-6
Frequency
Acceleration
Shock stress
In accordance with the standard EN 60068-2-27
Acceleration
Duration
Airgap creepage
In accordance with the standard EN 60664-1
Overvoltage category
Pollution degree
Protection type
In accordance with the standard EN 60529
Housing
Terminals
Mounting area (e.g. control cab-
inet)
Mechanical data
Mounting position
Material
Bottom
Front
Operating Manual PSSu K F FAU B, PSSu K F FAU P
1003434-EN-05
312420
0,65 - 3,75 ms
312420
EN 60068-2-1, EN 60068-2-14, EN
60068-2-2, EN 60068-2-30, EN
60068-2-78
0 - 60 °C
-40 - 70 °C
93 % r. h. at 40 °C
Not permitted
5000 m
EN 61000-4-2, EN 61000-4-3, EN
61000-4-4, EN 61000-4-5, EN
61000-4-6, EN 61000-6-2, EN
61000-6-4
10 - 150 Hz
1g
15g
11 ms
II
2
IP20
IP20
IP54
312420
vertical
PC
PC
312421
0,65 - 3,75 ms
312421
EN 60068-2-1, EN 60068-2-14, EN
60068-2-2, EN 60068-2-30, EN
60068-2-78
EN 60068-2-14
0 - 60 °C
EN 60068-2-1/-2
-40 - 70 °C
EN 60068-2-78
93 % r. h. at 40 °C
Not permitted
5000 m
EN 61000-4-2, EN 61000-4-3, EN
61000-4-4, EN 61000-4-5, EN
61000-4-6, EN 61000-6-2, EN
61000-6-4
EN 60068-2-6
10 - 150 Hz
1g
EN 60068-2-27
15g
11 ms
EN 60664-1
II
2
EN 60529
IP20
IP20
IP54
312421
vertical
PC
PC
| 67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pssu k f fau p312421312420

Table of Contents