Function description
Output data types
O-data
O-data type
name
O00 ...
FS_O_DO
O03
FS_O_FAU
Operating Manual PSSu K F FAU B, PSSu K F FAU P
1003434-EN-05
O-data element
Data: SAFEBOOL
DeactivateFastShutdownI0I1:
SAFEBOOL
DeactivateFastShutdownI2I3:
SAFEBOOL
DeactivateFastShutdownOSSD:
SAFEBOOL
DeactivateFastShutdownMute:
SAFEBOOL
ProtectedFieldModeBoxBending:
SAFEBOOL
ProtectedFieldModeBackGauge:
SAFEBOOL
SystemInit: SAFEBOOL
Acknowledge: SAFEBOOL
PowerOffTransmitter: SAFEBOOL TRUE: PSENvip switches from RUN to
SensorControl: SAFEBYTE
PressCycleState: SAFEBYTE
Meaning
Output data O00 ... O03
TRUE: Deactivate fast shutdown for input
pair I00 and I01
FALSE: Activate fast shutdown for input
pair I00 and I01
TRUE: Deactivate fast shutdown for input
pair I02 and I03
FALSE: Activate fast shutdown for input
pair I02 and I03
TRUE: Deactivate fast shutdown for
OSSD
FALSE: Activate fast shutdown for OSSD
TRUE: Deactivate fast shutdown for mute
FALSE: Activate fast shutdown for mute
TRUE: Activate box mode
FALSE: Deactivate box mode
TRUE: Activate back gauge mode
FALSE: Deactivate back gauge mode
TRUE: Activate system check
FALSE: Deactivate system check
TRUE: Acknowledge protected field mode
FALSE: Do not acknowledge protected
field mode
STANDBY state
FALSE: PSENvip switches from
STANDBY to RUN state
Byte for transferring the tool classes or the
muting end point from the user program to
the module. For further information see
chapter entitled
Communication with the
safety system [
26]
The user program sends the current press
status
TRUE: In preparation
FALSE: In preparation
| 25