Pilz PIT js2 Operating Manual

Pilz PIT js2 Operating Manual

Control and signal devices
Hide thumbs Also See for PIT js2:

Advertisement

Quick Links

PIT js2
Control and signal devices
Operating Manual­21130­EN­05

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PIT js2

  • Page 1 PIT js2 Control and signal devices Operating Manual­21130­EN­05...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries.  SD means Secure Digital...
  • Page 3: Table Of Contents

    Content Introduction Validity of documentation Retaining the documentation Definition of symbols For your safety Intended use Device description Function description Wiring Assignment Connection to evaluation device Dimensions in mm PIT js2 PIT js holder Technical Details Safety characteristic data Order reference Product Accessories Operating Manual PIT js2 21130­EN­05...
  • Page 4: Introduction

    PIT js2 Introduction Validity of documentation This documentation is valid for the product PIT js2. It is valid until new documentation is published. This documentation is valid for PIT js2 from the date of manufacture 2014­08. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Retaining the documentation This documentation is intended for instruction and should be retained for future reference. Definition of symbols Information that is particularly important is identified as follows: DANGER! This warning must be heeded! It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken. WARNING! This warning must be heeded! It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken. CAUTION! This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. NOTICE This describes a situation in which the product or devices could be dam­ aged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular import­ ance. Operating Manual PIT js2 21130­EN­05...
  • Page 5: For Your Safety

    PIT js2 INFORMATION This gives advice on applications and provides information on special fea­ tures. For your safety The unit may only be installed and commissioned by personnel who are familiar with both these instructions and the current regulations for health and safety at work and ac­ cident prevention. Ensure VDE and local regulations are met, especially those relating to protective measures. Any guarantee is rendered invalid if the housing is opened or unauthorised modifica­ tions are carried out. Check the function of the pushbutton before commissioning for the first time and then at regular intervals (at least annually). Intended use The PIT js2 is a manually operated command device that can be used as an enabling device. It allows authorised personnel to monitor processes in the danger zone of auto­ mated manufacturing facilities when movable guards are open. Additional protective measures (e.g. reduced speed) may be required relative to the result of the risk analysis! Use the following units as an evaluation device: PSS programmable safety system in conjunction with standard function block SB059 PNOZmulti modular safety system with the two­hand module Two­hand control relays – P2HZ X1 – P2HZ X1P – P2HZ X1.10P – P2HZ X2 – P2HZ X3 – P2HZ X4P PNOZelog safety relays – PNOZ e2.1p Device description The PIT js2 command device consists of a plastic housing with 3 pushbuttons. Features: 2 pushbuttons (ACT1 and ACT2) for the two­hand function (N/C / N/O contact, respect­...
  • Page 6: Function Description

    PIT js2 The contacts are connected by a coiled cable with an open end. Function description An enabling signal is generated in conjunction with a two­hand monitoring module by simul­ taneously pressing the ACT1 and ACT2 pushbuttons. This overrides the safety function of the movable guards. Authorised operating personnel then can enter the danger zone to monitor work processes. Releasing one or both pushbuttons ACT1 and ACT2 will interrupt the enabling signal. A subsequent enabling signal can only be generated once both pushbuttons have been re­ leased. Additionally, the Reset pushbutton can be incorporated into the control system to generate a subsequent enabling signal. Wiring Connect the ACT1 and ACT2 buttons to the control system in such a way that both pushbuttons must be actuated in order to generate an enabling signal. You can connect the Reset button to the control system such that, after releasing one or both pushbuttons ACT1 and ACT2, a subsequent enabling signal can only be gener­ ated once the Reset pushbutton has been actuated. Assignment ACT1 RESET ACT2 black blue black blue grey black white yellow purple brown green Operating Manual PIT js2 21130­EN­05...
  • Page 7: Connection To Evaluation Device

    PIT js2 Connection to evaluation device P2HZ X1 blue P2HZ X1P grey P2HZ X1.10P ACT1 black PNOZ e2.1p white ACT2 yellow P2HZ X2 grey blue P2HZ X4P black ACT1 yellow-grey black-red ACT2 yellow white P2HZX3 (Contact fuse protection, see grey blue technical details) black ACT1 yellow-grey black-red ACT2 yellow white PNOZmulti (with blue two­hand module) grey ACT1 black white...
  • Page 8 PIT js2 blue SafetyBUS p (with grey T1.2 ACT1 standard function black block SB059) T1.4 white T2.2 ACT2 yellow T2.4 purple RESET brown Reset Operating Manual PIT js2 21130­EN­05...
  • Page 9: Dimensions In Mm

    PIT js2 Dimensions in mm PIT js2 Operating Manual PIT js2 21130­EN­05...
  • Page 10: Pit Js Holder

    PIT js2 PIT js holder Technical Details General Approvals Electrical data Supply voltage Voltage 24 V Kind AC/DC Max. switching current, safety contacts 0,75 A Operating Manual PIT js2 21130­EN­05...
  • Page 11: Safety Characteristic Data

    PIT js2 Relay outputs Utilisation category DC 1 at 24 V Environmental data Ambient temperature Temperature range ­10 ­ 55 °C Protection type Housing IP50 Mechanical data Cable length L1 5,00 m Cable insulation material K1 Conductor cross section K1 0,14 mm² Material Housing – Dimensions Height 334,0 mm Width 74,0 mm Depth 60,0 mm Weight 764 g Safety characteristic data Safety characteristic data B10d in accordance with EN ISO 13849­1 and EN IEC 62061 20.000.000 Lambda /Lambda in accordance with EN IEC 62061 0,10 Order reference Product Type Features Order no.
  • Page 12 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 Switzerland +1 888-315-PILZ (315-7459) Austria +43 1 7986263-0 +41 62 88979-30 Mexico...

Table of Contents