Function description
MEASUREMENT state
MEASUREMENT mode can only be requested and ended via the add-on module PSENvip
IPM. The request to switch to measurement mode or to end measurement mode must be
sent to the special module PSENvip IPM by the press controller.
}
Switching to MEASUREMENT state
It is only possible to switch to MEASUREMENT state when PSENvip is in RUN state. The
press controller sends the command to start measurement mode to the add-on module
PSENvip IPM. The start command causes PSENvip to switch from RUN state to MEAS-
UREMENT state.
In MEASUREMENT state it is not possible to switch to ADJUSTMENT state and
TOOL CHANGE state (web interface). The Adjustment and Tool Change options are
deactivated in the web interface. Other requests are possible, but MEASUREMENT state
will be ended as a result.
}
End MEASUREMENT state
The press controller sends the command to stop measurement mode to the add-on mod-
ule PSENvip IPM. The stop command causes PSENvip to switch from MEASUREMENT
state to RUN state.
MEASUREMENT state can also be ended via an operating state with higher priority (e.g.
requesting STANDBY state via the PSS 4000 user program, ERROR state, IDLE state
due to ending the operating state "Device in RUN state without error" on the safety con-
troller).
Operating Manual PSSu K F FAU B, PSSu K F FAU P
1003434-EN-05
NOTICE
If PSENvip is in MEASUREMENT state, the press is prevented from operat-
ing in normal mode or productive mode. So for efficient operation, the time
at which measurement mode is requested must be tailored to the operations
of the press.
| 41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pssu k f fau p312421312420

Table of Contents