Every 250 Hours Maintenance; Method For Checking Oil Level In Final Drive Case, Adding Oil - Komatsu D37EX-24 Operation & Maintenance Manual

Bulldozer
Table of Contents

Advertisement

MAINTENANCE
When lubricating the lift cylinder bottom pin (1) and U-frame mounting pin (3), lower the blade to raise the
idler 1 to 2 cm from the ground, then stop the engine.
2.
By using a grease pump, pump in grease through the grease fitting.
3.
After greasing, wipe off any old grease that is pushed out.
(1) Lift cylinder bottom pin (1 place each of right and left)
(2) Lift cylinder head pin (1 place each of right and left)
(3) U-frame mounting pin (1 place each of right and left)
(4) Angle cylinder bottom pin (1 place each of right and
left)
(5) Angle cylinder head pin (1 place each of right and left)
(6) Tilt cylinder head pin (1 place each of right and left)
(7) Center ball pin (1 place)
(8) Pitch rod pin (2 places)
(9) Turnbuckle screw (2 places)
(10) Tilt cylinder bottom pin (1 place)

EVERY 250 HOURS MAINTENANCE

Maintenance for every 50 hours service should be performed at the same time.

METHOD FOR CHECKING OIL LEVEL IN FINAL DRIVE CASE, ADDING OIL

Immediately after the engine is stopped, its parts and oil are still very hot and may cause burn in-
jury. Wait for the temperature to go down, and then start the work.
If there is remaining pressure inside the case, the oil or plug may jump out. Loosen the plug slowly
to release the pressure.
Prepare a handle for the work.
k
k
WARNING
MAINTENANCE PROCEDURE