Inducement status (4): "4 Engine power is under heavy de-
ration."
Engine power can be restored temporarily from power derate. This engine power restoration works only
when the Inducement status is "Severe Inducement"and relieves back temporarily to the power deration of
the "Low level Inducement". The operator can restore engine power through the machine monitor. For the
engine power restoration procedure, refer to the section of "Temporary Restoration from Inducement" in this
manual. Once in "Severe Inducement" and it becomes necessary to restore engine power, use the engine
power restoration function to move the machine to a safe place and add DEF.
INDUCEMENT STRATEGY WHEN ABNORMALITIES ARE DETECTED IN THE
UREA SCR SYSTEM DEVICES (EXCEPT ABNORMALITIES IN THE EGR SYS-
TEM)
If any abnormality is detected in the DEF quality or in the Urea SCR system, the Inducement strategy is activat-
ed.
The inducement strategy progresses in 4 levels, "Warning",
"Continuous Warning", "Low level Inducement" and "Severe In-
ducement". The Inducement strategy includes visual alert by
the DEF system caution lamp, and Action Level displayed on
the machine monitor (2), and the audible alert by a buzzer and
stepwise engine power deration that advances to speed limita-
tion to low idle. Engine power deration starts with Action Level
"L03 (Low level Inducement)" and advances to further deration
when "L04 (Severe Inducement)" is displayed. If "L03" is dis-
played, move the machine to a safe place and contact your Ko-
matsu distributor.
The content of the warning can be checked on the "SCR Information" screen of the user menu.
Perform the following procedure.
Press F6 on the standard screen to display the "SCR Informa-
tion" screen of the user menu.
If the parking brake lever and work equipment lock lever to
LOCK position or the joystick (steering, directional and gear
shift lever) and blade control lever is in NEUTRAL position for
over 3 seconds, "SCR Information" screen of the user menu
will pop up automatically while the Urea SCR system is in In-
ducement.
EXPLANATION OF COMPONENTS